{"id":751,"date":"2023-11-27T15:50:40","date_gmt":"2023-11-27T14:50:40","guid":{"rendered":"https:\/\/dev.engiby.ch\/?page_id=751"},"modified":"2023-12-12T13:50:55","modified_gmt":"2023-12-12T12:50:55","slug":"modbus-tcp-trouble-shooting","status":"publish","type":"page","link":"https:\/\/engiby.ch\/cms\/web\/support\/modbus-tcp-trouble-shooting\/","title":{"rendered":"Modbus TCP Trouble shooting"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;0px||0px||true|&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_code _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;]<span><span><a href=\"https:\/\/engiby.ch\/cms\/web\/\">Accueil<\/a><\/span><\/span>[\/et_pb_code][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_post_title meta=&#8221;off&#8221; featured_image=&#8221;off&#8221; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; title_font=&#8221;|600|||||||&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_post_title][et_pb_divider color=&#8221;#EEEEEE&#8221; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; background_color=&#8221;RGBA(255,255,255,0)&#8221; global_colors_info=&#8221;{}&#8221;][\/et_pb_divider][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px||0px||true|false&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px||0px||true|false&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; hover_enabled=&#8221;0&#8243; global_colors_info=&#8221;{}&#8221; sticky_enabled=&#8221;0&#8243;]<\/p>\n<p>This document may help you to solve problems you may encounter when using the Modbus TCP protocol with the Engiby driver on Saia PCD<sup>\u00ae<\/sup><span>\u00a0<\/span>systems. Note that a good knowledge of the partner device is necessary to correctly configure the driver on the Saia PCD<sup>\u00ae<\/sup>.<\/p>\n<p>For trouble shooting Modbus RTU and ASCI (serial), please refer to this document:<span>\u00a0<\/span><a href=\"https:\/\/engiby.ch\/cms\/web\/support\/modbus-serial-trouble-shooting\/\">Modbus Trouble shooting<\/a><\/p>\n<p>Note also that a lot of information is also given in the Modbus FAQ documents<br \/>For Modbus 1 (obsolete) : at<span>\u00a0<\/span><a href=\"https:\/\/engiby.ch\/cms\/web\/support\/modbus-1-driver-faq-obsolete\/\">Modbus FAQ<\/a><br \/>For Modbus 2 : at<span>\u00a0<\/span><a href=\"https:\/\/engiby.ch\/cms\/web\/support\/modbus-2-driver-faq\/\">Modbus 2 Driver<\/a><\/p>\n<p>In very rare cases you may also encounter known and fixed problem of the driver itself. Here you can fined the list of the last modifications of the Modbus 2 driver :<span>\u00a0<\/span><a href=\"https:\/\/engiby.ch\/cms\/web\/support\/modbus-2-history\/\">Modbus 2 History<\/a><\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px||0px||true|false&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; header_2_font_size=&#8221;20px&#8221; custom_margin=&#8221;0px||0px||true|false&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Typical troubles with the Modbus Slave Driver<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px||0px||true|false&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p><strong>No TCP communication<span><br \/><\/span><\/strong>If no TCP connection is possible from the master, it is most probably a cabling problem, a bad network configuration or a configuration error of the Saia PCD<sup>\u00ae<\/sup>. In this case<br \/>check the cabling. LAN installations are generally of good quality, but ensure that all patch cables are placed correctly.<br \/>If you are connected over a router, ensure that the TCP or UDP port 502 is open and routed to the correct IP address.<br \/>Ensure that that Saia PCD<sup>\u00ae<\/sup><span>\u00a0<\/span>configuration is correct: IP communiation activated, correct IP address and subnet mask.<br \/>If possible try to establish a PG5 connection with the online option &#8216;SOCKET&#8217; from the same point as the Modbus master. If this<span>\u00a0<\/span><span>don&#8217;t work, don&#8217;t look further<\/span><span>\u00a0<\/span>for a Modbus problem.<br \/>These remarks are also valid if UDP is used.<\/p>\n<p><strong>No response<span><br \/><\/span><\/strong>TCP connection is possible but not replay is received by the master. Typical error are:<\/p>\n<ul>\n<li><span>You did not place any application FBox. In a simple slave program, after the &#8220;Slave Link&#8221; FBox a &#8220;Standard Application&#8221; FBox must be placed.<br \/>This error is also indicated by the error &#8216;Application timeout&#8217; in the Master FBox.<\/span><\/li>\n<li><span>Check the station address to which the master sends its request. This is shown online in the &#8220;Master Link&#8221; FBox.<br \/>The default value is 1, but some master send the request with address 0 or other. Adjust it in &#8220;Slave application&#8221; FBox.<\/span><\/li>\n<\/ul>\n<p><strong>Difficulties to reconnect after broken link<span><br \/><\/span><\/strong>In some cases, difficulties have been noticed to reconnect slaves after a break of the link (broken cables or powered off devices).<br \/>This is partially due to the fact that the PCD has a limited number of internal sockets. After a socket is closed (normally or because of broken link) the firmware needs some time to free the unused sockets.<br \/>Ensure that you are using a recent firmware and Modbus driver.<br \/>If possible use the UDP protocol instead of TCP. UDP is not specified as possible option in the Modbus specification but work well also. It is simpler and even more efficient.<br \/>It such difficulties remains, it may be worth to place one Modbus Link FBox for each Slave station (up to 10 are possible). In this case, less TCP connect\/disconnect is needed and the handling of the internal sockets is improved.<\/p>\n<p><strong>Modbus TCP dosn&#8217;t work in parallel of the EIBNet\/IP driver<span><br \/><\/span><\/strong>To be able to share the Open Data Mode (communication mode used for open TCP\/UDP) between several drivers (even using different TCP ports), the communication drivers must use a specific mechanism. This has been implemented in the following versions:<\/p>\n<ul>\n<li><span><strong>Modbus 2<\/strong>: version\u00a0<strong>2.5.057<\/strong>\u00a0(contact\u00a0<strong>Engiby<\/strong>\u00a0if an update is needed)<\/span><\/li>\n<li><span><strong>EIB Library<\/strong>\u00a0version\u00a0<strong>$2.5.302<\/strong>\u00a0for PG5 1.4 and\u00a0<strong>$2.6.041<\/strong>\u00a0for PG5 2.0 (contact Saia Burgess Controls if an update is needed)<\/span><\/li>\n<\/ul>\n<p>Furthermore, under PG5 2.x, it is necessary to activate the Open Data Mode initialisation in the Device Configurator.<br \/>Other &#8216;native&#8217; communication protocols, like S-Bus, Saia Modbus, HTTP or FTP are not concerned by this topic.<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_row _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px||0px||true|false&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221;][et_pb_text _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; header_2_font_size=&#8221;20px&#8221; custom_margin=&#8221;0px||0px||true|false&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<h2>Typical troubles with the Master Driver<\/h2>\n<p>[\/et_pb_text][et_pb_text _builder_version=&#8221;4.22.2&#8243; _module_preset=&#8221;default&#8221; custom_margin=&#8221;0px||0px||true|false&#8221; custom_padding=&#8221;0px||0px||true|false&#8221; global_colors_info=&#8221;{}&#8221;]<\/p>\n<p><strong>No TCP connection<span><br \/><\/span><\/strong>Same remarks as for the Slave driver.<\/p>\n<p><strong>Some requests remains without response<span><br \/><\/span><\/strong>In Modbus TCP, you must adjust the IP address of the concerned slave but also its station address. Some slaves expect the address 1, other the address 0 by default.<br \/>Some slaves do not supports all Modbus functions or have restriction on the number of requested values.<br \/>Check the following:<\/p>\n<ul>\n<li><span>The correct Modbus function is used<\/span><\/li>\n<li><span>The address from which values are requested is valid for the slave<\/span><\/li>\n<li><span>The number of requested values is supported by the slave<\/span><\/li>\n<\/ul>\n<p>All this information should be given in the manual of the slave device, else contact the manufacturer to obtain this information.<\/p>\n<p><strong>Error \u2018Slave message\u2019 in the Master FBox<span><br \/><\/span><\/strong>This error means that the slave refused the request and sent an error message back (also called &#8216;exception response&#8217;).<br \/>Typical causes are:<\/p>\n<ul>\n<li><span>The requested address is not valid for the slave.<\/span><\/li>\n<li><span>The range of the values to be read is bigger than the valid address range in the slave.<\/span><\/li>\n<li><span>A value sent is not accepted by the slave.<\/span><\/li>\n<\/ul>\n<p>Take care at the address offset option (0 or 1). If this option is not correctly set the address maybe shifted by one and be invalid for the slave.<br \/>E.g. address 25 in the master with offset=1, maybe understand as address 24 in the slave if the offset 1 is not applied by the slave. Address 24 may be invalid for the slave.<\/p>\n<p><strong>Modbus TCP don&#8217;t work the EIBNet\/IP driver<span><br \/><\/span><\/strong>Same comments as for the Slave Driver. See comments above.<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p><span><span><a href=\"https:\/\/engiby.ch\/cms\/web\/\">Accueil<\/a><\/span><\/span>This document may help you to solve problems you may encounter when using the Modbus TCP protocol with the Engiby driver on Saia PCD\u00ae\u00a0systems. Note that a good knowledge of the partner device is necessary to correctly configure the driver on the Saia PCD\u00ae. For trouble shooting Modbus RTU and ASCI (serial), please refer to [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":16,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[],"tags":[],"class_list":["post-751","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Modbus TCP Trouble shooting - Engiby<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Modbus TCP Trouble shooting - Engiby\" \/>\n<meta property=\"og:description\" content=\"This document may help you to solve problems you may encounter when using the Modbus TCP protocol with the Engiby driver on Saia PCD\u00ae\u00a0systems. Note that a good knowledge of the partner device is necessary to correctly configure the driver on the Saia PCD\u00ae. For trouble shooting Modbus RTU and ASCI (serial), please refer to [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/engiby.ch\/cms\/web\/support\/modbus-tcp-trouble-shooting\/\" \/>\n<meta property=\"og:site_name\" content=\"Engiby\" \/>\n<meta property=\"article:modified_time\" content=\"2023-12-12T12:50:55+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/support\\\/modbus-tcp-trouble-shooting\\\/\",\"url\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/support\\\/modbus-tcp-trouble-shooting\\\/\",\"name\":\"Modbus TCP Trouble shooting - Engiby\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/#website\"},\"datePublished\":\"2023-11-27T14:50:40+00:00\",\"dateModified\":\"2023-12-12T12:50:55+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/support\\\/modbus-tcp-trouble-shooting\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/support\\\/modbus-tcp-trouble-shooting\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/support\\\/modbus-tcp-trouble-shooting\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support\",\"item\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/support\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Modbus TCP Trouble shooting\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/#website\",\"url\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/\",\"name\":\"Engiby\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/#organization\",\"name\":\"Engiby Sarl\",\"url\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/LogoEngiby.jpg\",\"contentUrl\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/LogoEngiby.jpg\",\"width\":1180,\"height\":226,\"caption\":\"Engiby Sarl\"},\"image\":{\"@id\":\"https:\\\/\\\/engiby.ch\\\/cms\\\/web\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Modbus TCP Trouble shooting - Engiby","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"Modbus TCP Trouble shooting - Engiby","og_description":"This document may help you to solve problems you may encounter when using the Modbus TCP protocol with the Engiby driver on Saia PCD\u00ae\u00a0systems. Note that a good knowledge of the partner device is necessary to correctly configure the driver on the Saia PCD\u00ae. For trouble shooting Modbus RTU and ASCI (serial), please refer to [&hellip;]","og_url":"https:\/\/engiby.ch\/cms\/web\/support\/modbus-tcp-trouble-shooting\/","og_site_name":"Engiby","article_modified_time":"2023-12-12T12:50:55+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/engiby.ch\/cms\/web\/support\/modbus-tcp-trouble-shooting\/","url":"https:\/\/engiby.ch\/cms\/web\/support\/modbus-tcp-trouble-shooting\/","name":"Modbus TCP Trouble shooting - Engiby","isPartOf":{"@id":"https:\/\/engiby.ch\/cms\/web\/#website"},"datePublished":"2023-11-27T14:50:40+00:00","dateModified":"2023-12-12T12:50:55+00:00","breadcrumb":{"@id":"https:\/\/engiby.ch\/cms\/web\/support\/modbus-tcp-trouble-shooting\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/engiby.ch\/cms\/web\/support\/modbus-tcp-trouble-shooting\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/engiby.ch\/cms\/web\/support\/modbus-tcp-trouble-shooting\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/engiby.ch\/cms\/web\/"},{"@type":"ListItem","position":2,"name":"Support","item":"https:\/\/engiby.ch\/cms\/web\/support\/"},{"@type":"ListItem","position":3,"name":"Modbus TCP Trouble shooting"}]},{"@type":"WebSite","@id":"https:\/\/engiby.ch\/cms\/web\/#website","url":"https:\/\/engiby.ch\/cms\/web\/","name":"Engiby","description":"","publisher":{"@id":"https:\/\/engiby.ch\/cms\/web\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/engiby.ch\/cms\/web\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/engiby.ch\/cms\/web\/#organization","name":"Engiby Sarl","url":"https:\/\/engiby.ch\/cms\/web\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/engiby.ch\/cms\/web\/#\/schema\/logo\/image\/","url":"https:\/\/engiby.ch\/cms\/web\/wp-content\/uploads\/2025\/11\/LogoEngiby.jpg","contentUrl":"https:\/\/engiby.ch\/cms\/web\/wp-content\/uploads\/2025\/11\/LogoEngiby.jpg","width":1180,"height":226,"caption":"Engiby Sarl"},"image":{"@id":"https:\/\/engiby.ch\/cms\/web\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/pages\/751","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/comments?post=751"}],"version-history":[{"count":7,"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/pages\/751\/revisions"}],"predecessor-version":[{"id":1117,"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/pages\/751\/revisions\/1117"}],"up":[{"embeddable":true,"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/pages\/16"}],"wp:attachment":[{"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/media?parent=751"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/categories?post=751"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/engiby.ch\/cms\/web\/wp-json\/wp\/v2\/tags?post=751"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}